Wire-Free Interconnected Hardwired Smoke Alarm with Egress Light
P4010LACS-W
-
10-Year Sealed Lithium Battery: Eliminates late night battery chirp
-
Voice Notifications
-
Bug Screen: Protects alarm from insect ingression
-
Flashing LED Status Ring: Allows easy identification of current state of alarm
P/N 21027326
The P4010LACS-W is an AC/DC powered smoke alarm with 10-year battery backup that features supervised wire-free interconnect capability and provides enhanced intelligibility for users. The voice warning feature accompanies the 85dB tone during an alarm event, and helps reduce confusion with verbal announcements such as “Replace alarm” at end of alarm life, and “Hush mode activated” when a nuisance alarm is silenced.
During alarm mode, the safety light helps provide a lighted escape path. The three-color LED ring helps users quickly determine standby, alarm, or error mode of the alarm.
Kidde P4010 Series Alarms contain 10-year tamper proof batteries that eliminate the need for battery replacement, and ends worry over unauthorized removal. Users are further shielded from late night battery chirps by the unit’s Ambient Light Sensing feature, which establishes a day/night cycle and prevents alarm chirping in dark conditions.
Wire-Free or hardwire interconnect triggers each connected alarm in the home to sound once smoke is detected. This can provide more time to react. The National Fire Alarm and Signaling Code (NFPA 72) has required smoke alarms in new homes to be interconnected since 1989, which traditionally involves running wiring to each alarm. Older and remodeled homes can now be updated to current standards without having to run new interconnect wiring to each alarm (AC power wiring still required). Existing networks of interconnected alarms can be expanded with use of a single P4010LACS-W and additional Kidde Wire-Free alarms.
Additional benefits and features are available when used in conjunction with the Kidde RemoteLync Bridge, which connects P4010 Wire-Free alarms via your home’s Wi-Fi to your smart device. Additional information such as battery life and sensor health status are available from each assigned room location. Weather alerts, and intruder alerts (when used with the Kidde RemoteLync camera), can be sent to each connected alarm, creating an easy to install fire – security – weather – warning system from one network of devices.
- 10-Year Sealed Lithium Battery: Eliminates late night battery chirp
- Voice Notifications
- Bug Screen: Protects alarm from insect ingression
- Flashing LED Status Ring: Allows easy identification of current state of alarm
- Supervised Wire-Free Interconnect: Proprietary radio signal joins multiple alarms together, so when one alarm sounds they all sound. User is alerted if an alarm loses connection to the network.
- Sealed-in Lithium Battery: No battery replacement required over the 10 year life of the alarm. Eliminates worry about battery removal or unauthorized deactivation of alarm.
- Safety Light: Bright LEDs provide lighted escape path.
- Voice Notifications: Unit verbally announces “Fire!” and other alerts such as “Replace Alarm,” which helps the user better understand current status of the unit.
- Easy to Install: Simply turn the switch on the back of unit or mount to bracket to activate the alarm. Multiple units can be interconnected with push of one button.
- Photoelectric Sensor: Smoke alarm contains advanced photoelectric sensor that may detect visible particles (associated with smoldering fires) sooner than ionization alarms.
- Ambient Light Sensing: Establishes Day/Night cycle and prevents chirping during the night until the next Day cycle begins.
- Alarm Locate Feature: Quickly find initiating alarm by silencing other alarms in the network.
- Test / Hush® Button: Tests alarm circuitry and activates Hush® feature to temporarily silence nuisance alarms for up to 10 minutes. End of Unit Life and Network Error chirps can also be silenced.
- End of Unit Life Warning: Alerts user the alarm is in need of replacement.
- Compatible with RemoteLync Bridge: Connect to the Kidde app for additional features and benefits.
- 10-Year Limited Warranty
Technical Specifications
Model: |
P4010LACS-W |
Power Source: |
120VAC (60Hz 53mA Max) Sealed 3V Battery Backup |
SmokeSensor: | Photoelectric |
Audio Alarm: | 85dB at 10ft |
Temperature Range: | 40˚F (4.4˚C) to 100˚F (37.8˚C) |
Humidity Range: |
Up to 95% non-condensing relative humidity (RH) |
Size: | 5.59” in diameter x 1.91” depth |
Weight: | .6lb |
Interconnects: | Up to 24 Kidde devices |
Warranty: | 10 year limited |
Compatible Intelligent Wire-Free 10-Year Models
Architectural and Engineering Specifications
The smoke alarm model shall be P4010LACS-W or approved equal and is powered by a 120VAC, 60Hz source along with lithium battery backup. The lithium batteries shall be sealed in the unit to prevent removal and/or tampering. The unit shall incorporate a photoelectric sensor.
The smoke alarm can be installed on any standard single gang electrical box, up to a 4”octagon junction box, following the UL/Manufacturer’s approved placement guidelines.The electrical connection (to the alarm) shall be made with a plug-in connector. The alarm shall incorporate an activation switch that can be engaged with the included tool or screwdriver to power on the alarm at startup, and deactivate the alarm at end of alarm life.
The P4010LACS-W shall include a test button that will simulate a fire condition and cause the unit to go into alarm. This sequence tests the unit’s electronics to ensure proper operation. The safety light will illuminate while in test mode. A maximum of 24 Kidde devices can be interconnected in a multiple station arrangement. The interconnect system must not exceed the NFPA (National Fire Protection Association) limit of 18 initiating devices, of which 12 can be smoke alarms.
The unit shall have audible methods for warning of smoke or fire danger: a piezoelectric horn, rated at 85 decibels at 10 feet, and a voice warning. In alarm, the horn will sound in the repetitive manner – three long beeps, a 1.5 second pause, three long beeps, repeating. In between, the unit will announce a voice warning, “Fire!” The red LED ring will flash in conjunction with the alarm sound, and the safety light will illuminate..
The unit shall incorporate wireless alarm interconnect capability, whereas when one interconnected unit sounds an alarm, all other compatible wireless units in the wireless alarm network will alarm. The maximum distance between wireless interconnect models is greater than 300 feet in open air. The alarm interconnect shall be supervised, where an audible and visual indication is given if the alarm loses connection to other units in the network.
The unit shall at a minimum meet the requirements of UL217, NFPA 72, The State of California Fire Marshall, NFPA101 (One and two family dwellings), Federal Housing Authority (FHA), Housing and Urban Development (HUD). The alarm shall be UL Listed and shall include a 10-year manufacturer’s limited warranty.
Leading authorities recommend that both ionization and photoelectric smoke alarms be installed to help ensure maximum detection of the various types of fires that can occur within the home. Ionization sensing alarms may detect invisible fire particles (associated with fast flaming fires) sooner than photoelectric alarms. Photoelectric sensing alarms may detect visible fire particles (associated with slow smoldering fires) sooner than ionization alarms.
The P4010LACS-W is an AC/DC powered smoke alarm with 10-year battery backup that features supervised wire-free interconnect capability and provides enhanced intelligibility for users. The voice warning feature accompanies the 85dB tone during an alarm event, and helps reduce confusion with verbal announcements such as “Replace alarm” at end of alarm life, and “Hush mode activated” when a nuisance alarm is silenced.
During alarm mode, the safety light helps provide a lighted escape path. The three-color LED ring helps users quickly determine standby, alarm, or error mode of the alarm.
Kidde P4010 Series Alarms contain 10-year tamper proof batteries that eliminate the need for battery replacement, and ends worry over unauthorized removal. Users are further shielded from late night battery chirps by the unit’s Ambient Light Sensing feature, which establishes a day/night cycle and prevents alarm chirping in dark conditions.
Wire-Free or hardwire interconnect triggers each connected alarm in the home to sound once smoke is detected. This can provide more time to react. The National Fire Alarm and Signaling Code (NFPA 72) has required smoke alarms in new homes to be interconnected since 1989, which traditionally involves running wiring to each alarm. Older and remodeled homes can now be updated to current standards without having to run new interconnect wiring to each alarm (AC power wiring still required). Existing networks of interconnected alarms can be expanded with use of a single P4010LACS-W and additional Kidde Wire-Free alarms.
Additional benefits and features are available when used in conjunction with the Kidde RemoteLync Bridge, which connects P4010 Wire-Free alarms via your home’s Wi-Fi to your smart device. Additional information such as battery life and sensor health status are available from each assigned room location. Weather alerts, and intruder alerts (when used with the Kidde RemoteLync camera), can be sent to each connected alarm, creating an easy to install fire – security – weather – warning system from one network of devices.
- 10-Year Sealed Lithium Battery: Eliminates late night battery chirp
- Voice Notifications
- Bug Screen: Protects alarm from insect ingression
- Flashing LED Status Ring: Allows easy identification of current state of alarm
- Supervised Wire-Free Interconnect: Proprietary radio signal joins multiple alarms together, so when one alarm sounds they all sound. User is alerted if an alarm loses connection to the network.
- Sealed-in Lithium Battery: No battery replacement required over the 10 year life of the alarm. Eliminates worry about battery removal or unauthorized deactivation of alarm.
- Safety Light: Bright LEDs provide lighted escape path.
- Voice Notifications: Unit verbally announces “Fire!” and other alerts such as “Replace Alarm,” which helps the user better understand current status of the unit.
- Easy to Install: Simply turn the switch on the back of unit or mount to bracket to activate the alarm. Multiple units can be interconnected with push of one button.
- Photoelectric Sensor: Smoke alarm contains advanced photoelectric sensor that may detect visible particles (associated with smoldering fires) sooner than ionization alarms.
- Ambient Light Sensing: Establishes Day/Night cycle and prevents chirping during the night until the next Day cycle begins.
- Alarm Locate Feature: Quickly find initiating alarm by silencing other alarms in the network.
- Test / Hush® Button: Tests alarm circuitry and activates Hush® feature to temporarily silence nuisance alarms for up to 10 minutes. End of Unit Life and Network Error chirps can also be silenced.
- End of Unit Life Warning: Alerts user the alarm is in need of replacement.
- Compatible with RemoteLync Bridge: Connect to the Kidde app for additional features and benefits.
- 10-Year Limited Warranty
Technical Specifications
Model: |
P4010LACS-W |
Power Source: |
120VAC (60Hz 53mA Max) Sealed 3V Battery Backup |
SmokeSensor: | Photoelectric |
Audio Alarm: | 85dB at 10ft |
Temperature Range: | 40˚F (4.4˚C) to 100˚F (37.8˚C) |
Humidity Range: |
Up to 95% non-condensing relative humidity (RH) |
Size: | 5.59” in diameter x 1.91” depth |
Weight: | .6lb |
Interconnects: | Up to 24 Kidde devices |
Warranty: | 10 year limited |
Compatible Intelligent Wire-Free 10-Year Models
Architectural and Engineering Specifications
The smoke alarm model shall be P4010LACS-W or approved equal and is powered by a 120VAC, 60Hz source along with lithium battery backup. The lithium batteries shall be sealed in the unit to prevent removal and/or tampering. The unit shall incorporate a photoelectric sensor.
The smoke alarm can be installed on any standard single gang electrical box, up to a 4”octagon junction box, following the UL/Manufacturer’s approved placement guidelines.The electrical connection (to the alarm) shall be made with a plug-in connector. The alarm shall incorporate an activation switch that can be engaged with the included tool or screwdriver to power on the alarm at startup, and deactivate the alarm at end of alarm life.
The P4010LACS-W shall include a test button that will simulate a fire condition and cause the unit to go into alarm. This sequence tests the unit’s electronics to ensure proper operation. The safety light will illuminate while in test mode. A maximum of 24 Kidde devices can be interconnected in a multiple station arrangement. The interconnect system must not exceed the NFPA (National Fire Protection Association) limit of 18 initiating devices, of which 12 can be smoke alarms.
The unit shall have audible methods for warning of smoke or fire danger: a piezoelectric horn, rated at 85 decibels at 10 feet, and a voice warning. In alarm, the horn will sound in the repetitive manner – three long beeps, a 1.5 second pause, three long beeps, repeating. In between, the unit will announce a voice warning, “Fire!” The red LED ring will flash in conjunction with the alarm sound, and the safety light will illuminate..
The unit shall incorporate wireless alarm interconnect capability, whereas when one interconnected unit sounds an alarm, all other compatible wireless units in the wireless alarm network will alarm. The maximum distance between wireless interconnect models is greater than 300 feet in open air. The alarm interconnect shall be supervised, where an audible and visual indication is given if the alarm loses connection to other units in the network.
The unit shall at a minimum meet the requirements of UL217, NFPA 72, The State of California Fire Marshall, NFPA101 (One and two family dwellings), Federal Housing Authority (FHA), Housing and Urban Development (HUD). The alarm shall be UL Listed and shall include a 10-year manufacturer’s limited warranty.
Leading authorities recommend that both ionization and photoelectric smoke alarms be installed to help ensure maximum detection of the various types of fires that can occur within the home. Ionization sensing alarms may detect invisible fire particles (associated with fast flaming fires) sooner than photoelectric alarms. Photoelectric sensing alarms may detect visible fire particles (associated with slow smoldering fires) sooner than ionization alarms.